Click on part numbers below for data sheets:

9-35VDC
max. 3A
50-500Hz

direct mount on
DIN43650/A solenoid,
DIN43650/A cable connector

direct mount on
DIN43650/A solenoid,
3m long 4 x 18AWG cable

open board,
DIN rail mount

epoxy potted,
spade connectors

NEMA 4X plastic box

type

->

g.

.

.

.

.

.

. 

input

signals

|

V

convertible:
0-5V,
0-10V,
0-20mA
or
4-20mA

PVD3DIN

PVD3D3M

single: PVD3D1R

dual: PVD3D2R

single: PVD3D1E

dual: PVD3D2E

single: PVD3D1N

dual: PVD3D2N

bipolar
+/-10V
differential

PVD3XDN

PVD3X3M

dual: PVD3X2R

dual: PVD3X2E

dual: PVD3X2N

two ON/OFF
to select
one of four
pre-sets
per channel

PVD3SDN

PVD3S3M

single: PVD3S1R

dual: PVD3S2R

single: PVD3S1E

dual: PVD3S2E

single: PVD3S1N

dual: PVD3S2N

Click on part numbers above for data sheets.

For a list of all standard part number, please click here.

If you do not find exactly what you need or for custom products, please contact us.

  

The Standard PVD3DIN Proportional Valve Driver is an electronic device in the shape of a slightly larger DIN connector, mounted directly on the valve. It is powered by a regulated or unregulated DC supply or a battery (in mobile applications), it receives small power signals from a potentiometer, joystick, PLC, analogue output card, computer or other control device and delivers high power controlled current to the solenoid of a proportional valve in order to regulate through pressure or flow the motion of a hydraulic actuator.

There are a large number of possible options to customize the driver for special applications such as :

Special Connectors:

Special Inputs / Outputs:

Special operation:

click here for printer friendly version of the Data Sheet 

PVD3DIN, Proportional Valve Driver, Direct DIN solenoid mount, DIN cable connector

Features/Benefits:

Specifications:

Settings & Range:

Set-Up Procedure:

At power up the display shows the input or output signal, selected by rotating #; the input directly in V or mA, corresponding to the input range pre-selected; the output current in A. To enter set-up mode rotate *, the display will show the settings  sequentially: HI, Jg, LO, UP, dn, db, dF, in, di and SA. When you reach the setting that you want to modify, rotate up or down to the desired value. To modify another setting, rotate * again and repeat. The Driver is fully functional during the set-up procedure with any adjustments effective immediately (except the input range selection that becomes effective only after saving). In order to write the new settings in the memory and return to normal mode of operation, rotate * until the display shows SA and then rotate #. If you do not want to keep the new settings, you may disconnect and re-connect the Driver from the power supply.

WE RESERVE THE RIGHT TO DISCONTINUE MODELS OR CHANGE SPECIFICATIONS WITHOUT NOTICE OR INCURRING OBLIGATION